Skip to main content

Emporia Vue Gen 3 Power Monitoring is Compatible with ESPHome & Home Assistant

digiblur

What is the Emporia Vue?

We've covered the Gen 2 model in the previous video, but in a quick TL;DR. It's a box that goes in your breaker panel to measure the entire power usage in your home as well as breaking it down to 16 other circuits in your home for a more detailed usage. This isn't any AI, or guess work involved like other brands, it measures the real world usage of each of the 16 circuits you install the clamps on in the breaker panel.

Out of the box the unit is cloud only and feeds your data to another company for use! That's not what we want, it's our electricity usage pattern data! We want it in house and local! Luckily the Gen 3 contains an ESP32 just like the previous Gen 2 model.

alt text

What is the Gen 3 all about?

Purchase on Amazon (affiliate) - https://amzn.to/3wMOcKv
Purchase from Emporia - https://shop.emporiaenergy.com/collections/in-panel-energy-monitors

Pay attention to the models, there are 3 packages with 0, 8, and 16 additional CT clamps included.

As we stated above, the Gen 3 comes with an ESP32 again and actually the same power monitoring chips. They've only decreased the size in the board itself while changing all 2.5mm/3.5mm CT clamp plugs to Phoenix style plugs. This means you can now easily cut your CT clamp plugs to length instead of having miles of extra wire to deal with. Probably a good idea to crimp ferrules on them again though after you cut them.

Emporia also added an Ethenet connection, but I'm not comfortable nor do I think my local code allows low voltage to mix with high voltage. I'll stick to Wi-Fi as the antenna is provided with the punchout plug to stick out of the metal panel.

alt text

Can I put ESPHome on it?

Read more 👉👇

First you'll need to open it as there isn't a known OTA exploit at this time. There are 5 screws on the back. You'll need to use a BDM frame or solder to the pads on the back. It isn't that difficult, so pick your poison. What's a BDM Frame? See here

Cossid mapped out the ESP32 RX/TX pins for us below for use with a USB TTL adapter. Thanks Cossid!

alt text

Keep in mind, do not transpose the RX/TX pins like you normally do. RX goes to RX and TX goes to TX this time around.

I was able to trace down the I2C pins to the power monitoring chip but the same gen 2 ESPHome code for the sensors should work fine for the new Gen 3 model. I've included my config below but you can find the ESPHome custom component code at https://github.com/emporia-vue-local/esphome

Note: The config below is missing the Ethernet controller and two LEDs.

ESPHome Code

esphome:
name: emporiavue3

substitutions:
display_name: EmpVu3

external_components:
- source: github://emporia-vue-local/esphome@dev
components:
- emporia_vue

esp32:
board: esp32dev
framework:
type: esp-idf
version: recommended

preferences:
# the default of 1min is far too short--flash chip is rated
# for approx 100k writes.
flash_write_interval: "48h"

api:
ota:

logger:
logs:
sensor: INFO

wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
ap:

captive_portal:

i2c:
sda: 5
scl: 18
scan: false
frequency: 200kHz # recommended range is 50-200kHz
id: i2c_a

switch:
- platform: restart
name: Restart

time:
- platform: sntp
id: sntp_time

# these are called references in YAML. They allow you to reuse
# this configuration in each sensor, while only defining it once
.defaultfilters:
- &moving_avg
# we capture a new sample every 0.24 seconds, so the time can
# be calculated from the number of samples as n * 0.24.
sliding_window_moving_average:
# we average over the past 2.88 seconds
window_size: 24
# we push a new value every 1.44 seconds
send_every: 12
- &invert
# invert and filter out any values below 0.
lambda: 'return max(-x, 0.0f);'
- &pos
# filter out any values below 0.
lambda: 'return max(x, 0.0f);'
- &abs
# take the absolute value of the value
lambda: 'return abs(x);'

sensor:
- platform: emporia_vue
i2c_id: i2c_a
phases:
- id: phase_a # Verify that this specific phase/leg is connected to correct input wire color on device listed below
input: BLACK # Vue device wire color
calibration: 0.0194 # 0.022 is used as the default as starting point but may need adjusted to ensure accuracy
# To calculate new calibration value use the formula <in-use calibration value> * <accurate voltage> / <reporting voltage>
voltage:
name: "Phase R Voltage"
filters: [*pos, *pos]
- id: phase_b # Verify that this specific phase/leg is connected to correct input wire color on device listed below
input: RED # Vue device wire color
calibration: 0.0194 # 0.022 is used as the default as starting point but may need adjusted to ensure accuracy
# To calculate new calibration value use the formula <in-use calibration value> * <accurate voltage> / <reporting voltage>
voltage:
name: "Phase L Voltage"
filters: [*moving_avg, *pos]
ct_clamps:
- phase_id: phase_a
input: "A" # Verify the CT going to this device input also matches the phase/leg
power:
name: "Phase R Power"
id: phase_a_power
device_class: power
filters: [*moving_avg, *pos]
- phase_id: phase_b
input: "B" # Verify the CT going to this device input also matches the phase/leg
power:
name: "Phase L Power"
id: phase_b_power
device_class: power
filters: [*moving_avg, *pos]
# Pay close attention to set the phase_id for each breaker by matching it to the phase/leg it connects to in the panel
- { phase_id: phase_a, input: "1", power: { name: "Circuit 1 Power", id: cir1, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "2", power: { name: "Circuit 2 Power", id: cir2, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "3", power: { name: "Circuit 3 Power", id: cir3, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "4", power: { name: "Circuit 4 Power", id: cir4, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "5", power: { name: "Circuit 5 Power", id: cir5, filters: [ *moving_avg, *pos, multiply: 2 ] } }
- { phase_id: phase_a, input: "5", power: { name: "Circuit 5 Power", id: cir5, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "6", power: { name: "Circuit 6 Power", id: cir6, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "7", power: { name: "Circuit 7 Power", id: cir7, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "8", power: { name: "Circuit 8 Power", id: cir8, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "9", power: { name: "Circuit 9 Power", id: cir9, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_b, input: "10", power: { name: "Circuit 10 Power", id: cir10, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "11", power: { name: "Circuit 11 Power", id: cir11, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "12", power: { name: "Circuit 12 Power", id: cir12, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "13", power: { name: "Circuit 13 Power", id: cir13, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "14", power: { name: "Circuit 14 Power", id: cir14, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_b, input: "15", power: { name: "Circuit 15 Power", id: cir15, filters: [ *moving_avg, *pos ] } }
# - { phase_id: phase_a, input: "16", power: { name: "Circuit 16 Power", id: cir16, filters: [ *moving_avg, *pos ] } }
- platform: template
name: "Total Power"
lambda: return id(phase_a_power).state + id(phase_b_power).state;
update_interval: 10s
id: total_power
unit_of_measurement: "W"
- platform: total_daily_energy
name: "Total Daily Energy"
power_id: total_power
accuracy_decimals: 0
- { power_id: cir1, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 1 Daily Energy" }
- { power_id: cir2, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 2 Daily Energy" }
- { power_id: cir3, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 3 Daily Energy" }
- { power_id: cir4, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 4 Daily Energy" }
- { power_id: cir5, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 5 Daily Energy" }
- { power_id: cir6, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 6 Daily Energy" }
- { power_id: cir7, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 7 Daily Energy" }
- { power_id: cir8, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 8 Daily Energy" }
# - { power_id: cir9, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 9 Daily Energy" }
# - { power_id: cir10, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 10 Daily Energy" }
# - { power_id: cir11, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 11 Daily Energy" }
# - { power_id: cir12, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 12 Daily Energy" }
# - { power_id: cir13, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 13 Daily Energy" }
# - { power_id: cir14, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 14 Daily Energy" }
# - { power_id: cir15, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 15 Daily Energy" }
# - { power_id: cir16, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 16 Daily Energy" }

Additional Pictures

alt text

alt text

alt text

alt text

alt text

alt text

alt text

alt text

alt text

alt text

alt text

alt text

Purchase on Amazon (affiliate) - https://amzn.to/3wMOcKv
Purchase from Emporia - https://shop.emporiaenergy.com/collections/in-panel-energy-monitors

Additional Info

Join us in the #device forums on the digiblurDIY Discord or the Gen3 Discussion Thread on Github.